Skip to main content
How can we help?

AR-DV10 Clock & System Settings

Summary: Setting the AR-DV10’s clock and configuration items.

Clock

[MENU] > CLK > [ENT]. Type the date and time as YY-MM-DD HH:MM; 30 January 2018 at 15:00 is 1801301500, then [ENT]. To change it later, open CLK, press the arrow to copy the current time, press the arrow four times and [ENT] to enter the new time. There’s no daylight saving feature and the date and time go into recordings’ properties but not their file names.

Configuration Menu

[MENU] > CONFIG. Select a line (1-9), [ENT], change with the dial, [ENT].

  • BEEP 00-15, default 05.
  • VOL ATT 00-15, default 05 (the “VolATT” icon shows at 06 and above).
  • CONTRAST 00-40, default 30.
  • BACKLIGHT: OFF (default, saves power), CONT (always on) or AUTO (on with use, off after 5 s).
  • SQL.SKIP: ON (default) records only while the squelch is open.
  • RES.CODE: ON (default) adds a result code to PC command responses.
  • PROTECT: ON turns auto-store at switch-off off (default OFF).
  • RF-GAIN 000-255, default 000: manual gain, used with AGC set to RF-G.

Page 2

  • SYSTEM RESET: all menu settings return to factory defaults; memory is kept.
  • FULL RESET: all settings return to defaults and all memory data is deleted.
  • FACTORY MENU: restricted to AOR service.
  • FIRM: shows the firmware version. SER.: the serial number. SYS.UPDATE: firmware update (see AR-DV10 Backup, Restore & Firmware Update).

Remote Mode

Command control is available over USB. The command list is on AOR’s website. A remote icon shows on screen, and all controls except the red power switch and [ENT] are disabled; press [ENT] to stop remote mode.